What is a 33KV line?
33kV to 11kV transformers steps down the the voltage to a safe level, which is then distributed via 11kV feeders to homes and businesses. 33kV lines on the other hand involve much higher voltages and are used to distribute power from one small sub-station to another.
How much current is in 11KV line?
An 11 kV distribution circuit may carry 150 A in each of its three phases, thus transmitting a power of 3 MW. A 400 V final distribution circuit may carry 200 A in each of its three phases, thus transmitting a power of 150 kW.
How do you identify 33KV?
For the 11KV transmission line, generally Double Pole(DP) structure is used. In a transmission line, if three pieces of disc insulators per phase are connected, then the KV of the transmission line is 33KV.
How many amps are high voltage lines?
The line can carry 500-1000 amps depending on ambient weather conditions. Cooler temperatures, clouds, and wind help lower resistance, so the voltage can push more electrons (amperage) through the conductor matrix.
Why transmission is 11kV or 33kV 66kV?
But we already know that there are some voltage drop due to the resistance of the transmission lines. For this reason, they transmit 10% extra voltage. Sending Voltage = 10kV x 10% = 11kV. While the receiving end voltage are 10kV due to voltage drop.
How many kVA is 2000 amps?
kVA to Amps Conversion Chart
kVA | kW | 208 V |
---|---|---|
1,563 kVA | 1,250 kW | 4,338 A |
1,875 kVA | 1,500 kW | 5,204 A |
2,188 kVA | 1,750 kW | 6,073 A |
2,500 kVA | 2,000 kW | 6,939 A |
Why 11kV 22kv 33kv 66kv 132kv?
The reason is something historical. In olden days when the electricity becomes popular, the people had a misconception that in the transmission line there would be a voltage loss of around 10%. So in order to get 100 at the load point they started sending 110 from supply side. This is the reason.
How does a 33kV to 11kV transformer work?
33kV to 11kV transformers steps down the the voltage to a safe level, which is then distributed via 11kV feeders to homes and businesses. Many people question why the voltage is as high as 33kV in the first place.
How big of a clearance do you need for a high voltage line?
Clearances from Buildings of HT and EHT voltage lines IE Rule 80. Vertical Distance. High voltage lines up to 33KV. 3.7 Meter. Extra High Voltage. 3.7 Meter + Add 0.3 meter for every additional 33KV. Horizontal clearance between the conductor and Building. High Voltage Up to 11 KV. 1.2 Meter.
What is the voltage of an underground HV / MV / LV cable?
Underground telecommunication cable shall be with underground power cable of voltage exceeding 33 kV. Get access to premium HV/MV/LV technical articles, electrical engineering guides, research studies and much more! It helps you to shape up your technical skills in your everyday life as an electrical engineer.
What does capacity mean on a transformer kVA?
The capacity means for a given transformer how much electrical load can be put on this transformer. Say for a transformer of 230 / 12 volts and 60 VA capacity ( Single phase) The max load can be 5 Amps on 12 V side if the load is exceeded the transformer will get overheated and may burn off.